Troubleshooting: 'Device is Already in AT Mode' Error on a Laison LoRa DCU

Avatar

sdg.hope
2026-06-17 10:49
Last Edited 2026-06-17 11:14

If you are attempting to read a Laison LoRa DCU on the DCu software (GM3/GM4 Module Configure Parameter Tool) and receive the error message:

'Device is Already in AT Mode'

follow the steps below:

  1. Send the following AT command:

    ATO
    
  2. Then send:

    ATO0
    
  3. Wait a few minutes to allow the device to exit AT mode and return to normal operation.

  4. Attempt to read the DCU again.

  5. If the issue persists:

    • Reboot the DCU.

    • Wait for the device to reconnect to the network.

    • Try reading the DCU again.

  6. If the problem still occurs after rebooting the DCU, please contact the meter manufacturer or device supplier for further assistance.

Note: This issue typically occurs when the DCU remains in AT command mode and is unable to return to its normal communication state.


Tags: at commandsdculaisonlaison loraloramodem